Buyer Name: CEFAS
Buyer Address: Pakefield Road, Lowestoft, NR33 0HT, United Kingdom
Contact Name: Giovana Cousseau
Contact Email: procure@cefas.gov.uk
Buyer Name: CEFAS
Buyer Address: Pakefield Road, Lowestoft, NR33 0HT, United Kingdom
Contact Name: Giovana Cousseau
Contact Email: procure@cefas.gov.uk
The Chemistry Function at the Cefas Lowestoft Laboratory requires a gas chromatography system with a triple quadrupole mass detector (GC-QqQ-MS) to replace an aging instrument. The system will support monitoring and R&D projects assessing the chemical status of the marine environment. It must analyse trace levels of small compounds (<1000 Da), including polychlorinated biphenyls PCBs, organochlorine pesticides, and brominated flame retardants in liquid extracts, and enable method development for emerging contaminants. Ex-demonstration instruments under two years old may be proposed at a reduced price. Where an ex-demonstration instrument is proposed, this must be clearly declared in the supplier's quotation. This purchase is being conducted under the LUPC Framework Agreement: The Supply of Mass Spectrometry and Chromatography Equipment (LAB 1029 AP), Lot 3 - Gas Chromatographs with Mass Spectrometers. Scope of requirement: 1. Technical Requirement The requirement is for a fully automated, bench-top GC-QqQ-MS system capable of high-throughput analysis with robust performance for a wide range of sample matrices. The system must deliver high sensitivity, low detection limits, and excellent long-term stability, supporting both routine and research applications. The objective is to enhance analytical capacity, improve data quality, and ensure compliance with relevant standards (e.g., ISO 17025). Application notes that demonstrate this type of performance should be provided. The system must consist of the following parts: 1.1 Automated sample introduction systems consisted of: • an autosampler for liquid sample extracts able to inject from small volume sample extracts (i.e. from 50 µL or less) equipped with a sample tray for at least 80 sample vials (2 ml, 12x32mm). 1.2 Gas Chromatograph (GC) must: • have internal gas flows managed via electronic pressure control, • have at least a split/splitless injection system, and optionally a PTV injector, • be capable of "fast" chromatography using short (sub 20m length), narrow columns (sub 0.18 mm i.d), • have oven temperatures ranging from ambient to at least 350°C, • have an independently heated transfer line to the detector 1.3 Triple quadrupole mass selective detector (QqQ-MS). With the following characteristics at a minimum: • Ionisation modes: EI and CI (positive and negative). • Usable mass rang: ≥20-1000 Da. • Q1 Mass Resolution: <1 Da. • Inert ion source (temperature range to at least 350°C). • Customisable internal calibration and mass tuning. • Easy source removal for cleaning. • Dual filament for EI. • Automated and manual MS tuning. • High-capacity pumping system. • A statement of scan rate (u/s), MRM/SRM speed (in transition/sec), minimum MRM/SRM dwell time is to be provided. • A statement of typical instrument detection limits, linearity, accuracy and precision.
No linked documents found for this notice.
{
"awards": [
{
"contractPeriod": {
"endDate": "2027-03-31T23:59:59+01:00",
"startDate": "2026-02-02T00:00:00Z"
},
"date": "2026-01-30T00:00:00Z",
"datePublished": "2026-02-03T09:22:00Z",
"documents": [
{
"datePublished": "2026-02-03T09:22:00Z",
"description": "Awarded contract notice on Contracts Finder",
"documentType": "awardNotice",
"format": "text/html",
"id": "1",
"language": "en",
"url": "https://www.contractsfinder.service.gov.uk/Notice/f78725a1-e12a-4bd1-969d-6186a2fb0264"
}
],
"id": "ocds-b5fd17-4f043502-2f29-48ec-8d03-34b5dde5811a-1",
"status": "active",
"suppliers": [
{
"id": "GB-CFS-321595",
"name": "Agilent Technologies LDA UK Ltd"
}
],
"value": {
"amount": 125912.92,
"currency": "GBP"
}
}
],
"buyer": {
"id": "GB-CFS-235542",
"name": "CEFAS"
},
"date": "2026-02-03T09:22:00Z",
"id": "f78725a1-e12a-4bd1-969d-6186a2fb0264-881844",
"initiationType": "tender",
"language": "en",
"ocid": "ocds-b5fd17-4f043502-2f29-48ec-8d03-34b5dde5811a",
"parties": [
{
"address": {
"countryName": "United Kingdom",
"locality": "Lowestoft",
"postalCode": "NR33 0HT",
"streetAddress": "Pakefield Road"
},
"contactPoint": {
"email": "procure@cefas.gov.uk",
"name": "Giovana Cousseau"
},
"id": "GB-CFS-235542",
"identifier": {
"legalName": "CEFAS"
},
"name": "CEFAS",
"roles": [
"buyer"
]
},
{
"address": {
"streetAddress": "5500 Lakeside\r\nCheadle Royal Business Park\r\nCheadle SK8 3GR"
},
"id": "GB-CFS-321595",
"identifier": {
"legalName": "Agilent Technologies LDA UK Ltd"
},
"name": "Agilent Technologies LDA UK Ltd",
"roles": [
"supplier"
]
}
],
"tag": [
"award"
],
"tender": {
"classification": {
"description": "Mass spectrometer",
"id": "38433100",
"scheme": "CPV"
},
"contractPeriod": {
"endDate": "2027-03-31T23:59:59+01:00",
"startDate": "2026-02-02T00:00:00Z"
},
"description": "The Chemistry Function at the Cefas Lowestoft Laboratory requires a gas chromatography system with a triple quadrupole mass detector (GC-QqQ-MS) to replace an aging instrument. The system will support monitoring and R\u0026D projects assessing the chemical status of the marine environment. It must analyse trace levels of small compounds (\u003c1000 Da), including polychlorinated biphenyls PCBs, organochlorine pesticides, and brominated flame retardants in liquid extracts, and enable method development for emerging contaminants. Ex-demonstration instruments under two years old may be proposed at a reduced price. Where an ex-demonstration instrument is proposed, this must be clearly declared in the supplier\u0027s quotation.\r\n\r\nThis purchase is being conducted under the LUPC Framework Agreement: The Supply of Mass Spectrometry and Chromatography Equipment (LAB 1029 AP), Lot 3 - Gas Chromatographs with Mass Spectrometers.\r\n\r\nScope of requirement:\r\n1. Technical Requirement\r\nThe requirement is for a fully automated, bench-top GC-QqQ-MS system capable of high-throughput analysis with robust performance for a wide range of sample matrices. The system must deliver high sensitivity, low detection limits, and excellent long-term stability, supporting both routine and research applications. The objective is to enhance analytical capacity, improve data quality, and ensure compliance with relevant standards (e.g., ISO 17025). Application notes that demonstrate this type of performance should be provided.\r\nThe system must consist of the following parts:\r\n1.1 Automated sample introduction systems consisted of:\r\n\u2022 an autosampler for liquid sample extracts able to inject from small volume sample extracts (i.e. from 50 \u00b5L or less) equipped with a sample tray for at least 80 sample vials (2 ml, 12x32mm).\r\n1.2 Gas Chromatograph (GC) must:\r\n\u2022 have internal gas flows managed via electronic pressure control,\r\n\u2022 have at least a split/splitless injection system, and optionally a PTV injector,\r\n\u2022 be capable of \"fast\" chromatography using short (sub 20m length), narrow columns (sub 0.18 mm i.d),\r\n\u2022 have oven temperatures ranging from ambient to at least 350\u00b0C,\r\n\u2022 have an independently heated transfer line to the detector\r\n1.3 Triple quadrupole mass selective detector (QqQ-MS). With the following characteristics at a minimum:\r\n\u2022 Ionisation modes: EI and CI (positive and negative).\r\n\u2022 Usable mass rang: \u226520-1000 Da.\r\n\u2022 Q1 Mass Resolution: \u003c1 Da.\r\n\u2022 Inert ion source (temperature range to at least 350\u00b0C).\r\n\u2022 Customisable internal calibration and mass tuning.\r\n\u2022 Easy source removal for cleaning.\r\n\u2022 Dual filament for EI.\r\n\u2022 Automated and manual MS tuning.\r\n\u2022 High-capacity pumping system.\r\n\u2022 A statement of scan rate (u/s), MRM/SRM speed (in transition/sec), minimum MRM/SRM dwell time is to be provided.\r\n\u2022 A statement of typical instrument detection limits, linearity, accuracy and precision.",
"id": "CF-0602300D8d000003VQwdEAG",
"items": [
{
"deliveryAddresses": [
{
"postalCode": "NR33 0HT"
},
{
"countryName": "British Oversea Territories"
},
{
"countryName": "Channel Islands"
},
{
"countryName": "Europe"
},
{
"countryName": "Isle of Man"
},
{
"countryName": "Rest of the World"
},
{
"countryName": "United Kingdom"
}
],
"id": "1"
}
],
"mainProcurementCategory": "goods",
"procurementMethod": "selective",
"procurementMethodDetails": "Call-off from a framework agreement",
"status": "complete",
"suitability": {
"sme": true,
"vcse": true
},
"tenderPeriod": {
"endDate": "2026-01-08T12:00:00Z"
},
"title": "CEFAS25-136 Gas Chromatography Tandem Triple Quadrupole Mass Spectrometer System",
"value": {
"amount": 104927.43,
"currency": "GBP"
}
}
}