← Back to opportunities

CEFAS24-83 Contract for onsite pipette clinic for Maintenance, Calibration & Repair

Cefas

Buyer Contact Info

Buyer Name: Cefas

Buyer Address: Pakefield Road, Lowestoft, NR33 0HT, GB

Contact Name: Laura Anderson

Contact Email: procure@cefas.gov.uk

Status
complete
Procedure
open
Value
50000.0 GBP
Published
11 Sep 2025, 07:39
Deadline
07 Aug 2024, 11:00
Contract Start
19 Sep 2024, 23:00
Contract End
22 Sep 2026, 22:59
Category
services
CPV
50433000 - Calibration services
Region
n/a
Awarded To
Starlab
Official Source
Open Contracts Finder

Description

1. Background The Cefas Weymouth laboratory has some 250+ pipettes that require annual and/or two yearly preventative maintenance, service, calibration, and repair. We have various brands, including:- Eppendorf, Gilson, Sartorius, Rainin (Mettler Toledo), Biohit, HTL, Thermo Electron, Labsystems and Fisherbrand. As an example, in molecular, virology and tissue culture areas, pipettes are used for the detection, isolation, and identification of aquatic diseases. This ranges from handling tissue homogenates, extracted DNA/RNA, to simply aliquoting out reagents precisely. There is similar usage in our other laboratory areas. The Cefas labs currently undertake testing work to ISO/IEC 17025. Therefore, the supplier must also be accredited to ISO17025 to undertake the calibration work. 2. Requirements 2.1. Pipette Clinic Cefas require the Supplier to: 2.1.1. Provide the services via an annual onsite clinic at the Weymouth laboratory. To be run over 3 to 4 weeks, Ideally in the January of each year, with preferred start dates for January 2025 being week of 6th or week of 13th. 2.2. Training / Support for Cefas Laboratory Staff In addition to the pipette services, Cefas require the Supplier to: 2.2.1. provide onsite workshops/training in calibration requirements, including how to identify the different types, the limitations of the workings of pipettes and how to select correct calibration and service levels needed. Also to explain difference between manufacturers and standard ISO level calibration and how it relates to usage.

Linked Documents

Select a document to preview.

Opportunity Context

Raw Notice JSON

Expand raw payload
{
  "awards": [
    {
      "contractPeriod": {
        "endDate": "2026-09-22T23:59:59+01:00",
        "startDate": "2024-09-20T00:00:00+01:00"
      },
      "date": "2024-09-17T00:00:00+01:00",
      "datePublished": "2025-09-11T08:39:22+01:00",
      "documents": [
        {
          "datePublished": "2025-09-11T08:39:22+01:00",
          "description": "Awarded contract notice on Contracts Finder",
          "documentType": "awardNotice",
          "format": "text/html",
          "id": "3",
          "language": "en",
          "url": "https://www.contractsfinder.service.gov.uk/Notice/7ab237da-7bed-47f3-af1a-4090a6292cfb"
        },
        {
          "description": "CEFAS24-83 Cefas_Short_Form_Contract FINAL SIGNED_Redacted",
          "format": "application/pdf",
          "id": "4",
          "url": "https://www.contractsfinder.service.gov.uk/Notice/Attachment/c38d1b9f-4de1-49fe-924d-a225e7db72bf"
        }
      ],
      "id": "ocds-b5fd17-ddca11fc-a4b4-4332-a625-ae40b3f1fe51-2",
      "status": "active",
      "suppliers": [
        {
          "id": "GB-CFS-266146",
          "name": "Starlab"
        }
      ],
      "value": {
        "amount": 50000,
        "currency": "GBP"
      }
    }
  ],
  "buyer": {
    "id": "GB-CFS-228030",
    "name": "Cefas"
  },
  "date": "2025-09-11T08:39:22+01:00",
  "id": "7ab237da-7bed-47f3-af1a-4090a6292cfb-863100",
  "initiationType": "tender",
  "language": "en",
  "ocid": "ocds-b5fd17-ddca11fc-a4b4-4332-a625-ae40b3f1fe51",
  "parties": [
    {
      "address": {
        "countryName": "GB",
        "locality": "Lowestoft",
        "postalCode": "NR33 0HT",
        "streetAddress": "Pakefield Road"
      },
      "contactPoint": {
        "email": "procure@cefas.gov.uk",
        "name": "Laura Anderson"
      },
      "id": "GB-CFS-228030",
      "identifier": {
        "legalName": "Cefas"
      },
      "name": "Cefas",
      "roles": [
        "buyer"
      ]
    },
    {
      "address": {
        "streetAddress": "5 Tanners Drive Blakelands MK14 5BU"
      },
      "id": "GB-CFS-266146",
      "identifier": {
        "legalName": "Starlab"
      },
      "name": "Starlab",
      "roles": [
        "supplier"
      ]
    }
  ],
  "tag": [
    "award"
  ],
  "tender": {
    "classification": {
      "description": "Calibration services",
      "id": "50433000",
      "scheme": "CPV"
    },
    "contractPeriod": {
      "endDate": "2026-09-22T23:59:59+01:00",
      "startDate": "2024-09-20T00:00:00+01:00"
    },
    "description": "1. Background\r\n\r\nThe Cefas Weymouth laboratory has some 250+ pipettes that require annual and/or two yearly preventative maintenance, service, calibration, and repair. We have various brands, including:- Eppendorf, Gilson, Sartorius, Rainin (Mettler Toledo), Biohit, HTL, Thermo Electron, Labsystems and Fisherbrand.\r\n\r\nAs an example, in molecular, virology and tissue culture areas, pipettes are used for the detection, isolation, and identification of aquatic diseases. This ranges from handling tissue homogenates, extracted DNA/RNA, to simply aliquoting out reagents precisely. There is similar usage in our other laboratory areas.\r\nThe Cefas labs currently undertake testing work to ISO/IEC 17025. Therefore, the supplier must also be accredited to ISO17025 to undertake the calibration work.\r\n2. Requirements\r\n\r\n2.1. Pipette Clinic\r\n\r\nCefas require the Supplier to:\r\n2.1.1. Provide the services via an annual onsite clinic at the Weymouth laboratory. To be run over 3 to 4 weeks, Ideally in the January of each year, with preferred start dates for January 2025 being week of 6th or week of 13th.\r\n2.2. Training / Support for Cefas Laboratory Staff\r\nIn addition to the pipette services, Cefas require the Supplier to:\r\n2.2.1. provide onsite workshops/training in calibration requirements, including how to identify the different types, the limitations of the workings of pipettes and how to select correct calibration and service levels needed. Also to explain difference between manufacturers and standard ISO level calibration and how it relates to usage.",
    "id": "CF-0367400D8d000003VQwdEAG",
    "items": [
      {
        "deliveryAddresses": [
          {
            "postalCode": "NR33 0HT"
          },
          {
            "countryName": "British Oversea Territories"
          },
          {
            "countryName": "Channel Islands"
          },
          {
            "countryName": "Europe"
          },
          {
            "countryName": "Isle of Man"
          },
          {
            "countryName": "Rest of the World"
          },
          {
            "countryName": "United Kingdom"
          }
        ],
        "id": "1"
      }
    ],
    "mainProcurementCategory": "services",
    "procurementMethod": "open",
    "procurementMethodDetails": "Open procedure (below threshold)",
    "status": "complete",
    "suitability": {
      "sme": true,
      "vcse": false
    },
    "tenderPeriod": {
      "endDate": "2024-08-07T12:00:00+01:00"
    },
    "title": "CEFAS24-83 Contract for onsite pipette clinic for Maintenance, Calibration \u0026 Repair",
    "value": {
      "amount": 50000,
      "currency": "GBP"
    }
  }
}